F-Gas record keeping

F-Gas records for businesses: what to keep and why

If your business operates air conditioning or refrigeration above certain refrigerant thresholds, you are responsible for keeping records of leak checks, repairs and refrigerant handling.

Many business owners assume F-Gas compliance is entirely the engineer's job. Engineers do carry out the regulated work, but the legal responsibility for leak checking and record keeping generally sits with the operator of the equipment, which is usually the business that runs it.

This guide explains in plain terms what records are expected, which systems they apply to and how to keep them without it becoming a burden. It is a general overview; for your own obligations, check current government guidance or ask us to look at your equipment.

Want to keep your system running well? See our air conditioning servicing and maintenance service.

Need this sorted?

Get a quote from TMS for air conditioning maintenance contracts.

F-Gas records for businesses: what to keep and why

Who counts as the operator

The operator is the person or business with actual control over the technical functioning of the equipment. In practice, that is usually the business that owns or uses the system day to day, such as a restaurant with its own cold room or an office tenant with its own air conditioning. In some leases the landlord holds that role for shared plant.

If you are not sure whether you or your landlord is the operator, check the lease and agree it in writing, because the responsibilities follow that role.

Which equipment needs records

Leak checking and record keeping apply to equipment containing fluorinated gases above set thresholds, which are expressed in tonnes of CO2 equivalent. That figure depends both on the amount of refrigerant and on its global warming potential, so a small charge of a high-impact refrigerant can cross the threshold while a larger charge of a lower-impact one may not.

Many commercial cold rooms, larger display systems, multi-split and VRF air conditioning systems fall within the requirements. Small domestic split systems usually fall below them. An engineer can work out the figure for each system from its nameplate.

What the records should include

Records generally have to be kept for a set number of years and be available if an enforcing authority asks for them.

  • The type and quantity of refrigerant in each system
  • Dates and results of leak checks
  • Details of any leaks found and the repairs carried out
  • Quantities of refrigerant added, and why
  • Quantities recovered, for example during repair or decommissioning
  • The company and engineer who carried out the work

Leak check frequency

How often leak checks are required depends on the size of the system in CO2 equivalent terms, with larger systems checked more often. Fitting an automatic leak detection system can reduce the required frequency for some equipment, and the largest systems must have leak detection fitted.

Our F-Gas regulations guide sets out the bands. A maintenance contract can be scheduled to match the leak check intervals so you are never caught out.

What happens when a leak is found

A leak should be repaired without undue delay, and the repair should be followed by a further check to confirm it has worked. Simply topping up a leaking system without repair is not good practice and should not be accepted. All of this goes in the records.

Keeping records simple

  • Ask your engineer to provide a written report after every visit
  • Keep an asset register listing every system, its location and refrigerant
  • Store reports in one place, paper or digital, that more than one person can reach
  • Update the register when systems are added, replaced or removed

Why it matters beyond compliance

Good records show trends. A system that needs refrigerant every year has a leak that is costing money, harming the environment and putting stock or comfort at risk. Records also help when budgeting for replacements, dealing with insurers and handing over a building to a new tenant or owner.

When systems change hands

When you buy a business, take on a lease or replace equipment, ask for the existing F-Gas records and asset register. Gaps in records make it harder to show compliance and to spot systems with a leak history. If nothing exists, a survey can identify each system, its refrigerant and charge, and start a new register from that point.

Decommissioning and disposal

When a system is removed, its refrigerant must be recovered by a certified engineer rather than released, and the quantity recovered should be recorded. The equipment then needs disposing of correctly. If you are refitting premises, include safe removal of old air conditioning and refrigeration in the plan. Our air conditioning removal service covers recovery and safe disconnection.

How we help

Our maintenance contracts include a written report, asset register and remedial quotes, which gives you most of what you need to hold. Our engineers are F-Gas qualified and record refrigerant handling on every relevant job.

Want a professional to handle it?

Send us a message

Free, no-obligation · Friendly local team · 24h response

FAQs

Common questions

Who is responsible for F-Gas records, me or my engineer?

Generally the operator of the equipment, usually the business that controls it. Your engineer carries out the work and provides the information you need to keep.

Does my small office air conditioning need F-Gas records?

It depends on the refrigerant type and charge. Small single splits often fall below the threshold; larger systems usually do not. An engineer can check.

What should an F-Gas record show?

Refrigerant type and quantity, leak check dates and results, leaks and repairs, refrigerant added or recovered, and who did the work.

Is it acceptable to just top up a leaking system?

No. Leaks should be found and repaired, then rechecked. Topping up alone is not good practice.