R404A phase-out: what it means for commercial refrigeration
For many years R404A was the refrigerant of choice in commercial freezers, cold rooms and display cabinets. It works well at low temperatures, but it has a very high global warming potential, and that has put it at the centre of the F-Gas phase-down.
If your business runs refrigeration that is more than a few years old, there is a good chance some of it uses R404A or a similar high-impact refrigerant. This guide explains what the rules mean in practice, what options exist and how to plan rather than react. Rules can change, so confirm current details before making decisions.
Need this sorted?
Get a quote from TMS for commercial refrigeration repairs.

Why R404A is being phased down
The F-Gas rules aim to cut emissions of fluorinated gases by reducing the amount placed on the market and restricting the highest-impact refrigerants. R404A has a global warming potential several thousand times that of carbon dioxide, so any leak has a large climate impact.
As supply is restricted, high-GWP refrigerants also tend to become harder to obtain and more expensive, which affects running and repair costs even where use is still allowed.
What the restrictions cover
The restrictions include a ban on placing new stationary refrigeration equipment on the market that uses refrigerants above a set GWP limit, which rules out R404A in new equipment. There are also restrictions on using new, virgin high-GWP refrigerant to service larger existing systems, with reclaimed or recycled refrigerant allowed for a limited period.
Existing systems can generally keep running, and they can be repaired, but topping them up becomes more restricted and more expensive over time. An engineer can tell you where each of your systems stands.
How to tell what refrigerant you have
Every refrigeration system has a nameplate, usually on the condensing unit, listing the refrigerant type and charge. Your F-Gas records and service reports should also show it. If you do not have records, a service visit can identify the refrigerant in each system and start an asset register.
Your options for an R404A system
Which option makes sense depends on the age and condition of the equipment, how critical it is, how often it has leaked and your budget. There is no single right answer.
- Keep running and maintain carefully, minimising leaks, while planning replacement
- Retrofit to a lower-GWP replacement refrigerant, where suitable for the equipment
- Replace the condensing unit or whole system with equipment designed for a lower-GWP refrigerant
About retrofitting
Some lower-GWP refrigerants have been developed as replacements for R404A in existing systems. Retrofitting usually involves recovering the old refrigerant, checking components and settings, possibly changing the oil or expansion valve, and recharging. It can extend the life of sound equipment.
It is not suitable for every system, and the replacement refrigerants behave slightly differently, so performance needs checking afterwards. An old, worn system with a history of leaks is often a poor candidate.
When replacement makes more sense
If a system is old, leaks repeatedly, has a failing compressor or no longer holds temperature reliably, replacing it rather than spending on retrofit or repeated repairs usually gives better value. New equipment is typically more efficient, which helps running costs too.
Planning replacement during a quieter trading period is far better than replacing in an emergency after a breakdown in summer.
Reducing the risk in the meantime
- Keep up regular leak checks and servicing
- Repair leaks promptly rather than topping up
- Keep condensers clean so the system is not overworked
- Fit temperature alarms so failures are caught before stock is lost
Air conditioning is affected too
The phase-down is not only about refrigeration. Air conditioning has also moved to lower-GWP refrigerants, which is why most new split systems use R32 rather than R410A. Our guide to R32 versus R410A explains that change. If your business has both older refrigeration and older air conditioning, it makes sense to review both together.
Questions to ask about each system
- What refrigerant does it use, and how much?
- How old is it, and how often has it needed repairs or refrigerant?
- How critical is it to the business if it fails?
- Is retrofit suitable, or is replacement the better long-term option?
- When is a convenient time to carry out any work?
Planning ahead
A simple plan lists each system, its refrigerant, age and condition, and ranks them by risk. That turns the phase-down from a worry into a budget line. We can survey your refrigeration, identify which systems use high-GWP refrigerant and advise on repair, retrofit or replacement for each.
Want a professional to handle it?
Related services
- Commercial refrigeration repairs
- Display refrigeration cabinets
- Cold room installation and repair
- Ice machine installation, servicing and repair
Covering Hertfordshire, Buckinghamshire, Bedfordshire and London.
FAQs
Common questions
Is R404A banned?
It is banned in new stationary refrigeration equipment and restricted for servicing larger existing systems. Existing systems can generally keep running and be repaired.
Can I still get my R404A system repaired?
Generally yes, though refrigerant availability and servicing restrictions affect what can be done and the cost. An engineer can advise for your system.
What replaces R404A?
Lower-GWP refrigerants are used in new equipment, and some are designed as retrofit replacements in existing systems where suitable.
Should I retrofit or replace?
It depends on age, condition and leak history. Sound, newer equipment may suit retrofit; old, leaking systems are usually better replaced.
How do I know if my fridge uses R404A?
Check the nameplate on the condensing unit, or your F-Gas records and service reports.
Keep reading
More from our knowledge base
Fault & symptom guides
Signs your commercial fridge compressor is failing
The compressor is the heart of any fridge or freezer; catching the warning signs early can save the compressor, or at least save your stock.
Cost & process guides
Refrigeration temperature monitoring and alarms: protecting your stock
A temperature alarm turns a breakdown you discover in the morning into one you hear about in time to save the stock.
Cost & process guides
How to reduce commercial refrigeration energy costs
Refrigeration runs every hour of every day, so small improvements in how it is maintained, used and sited add up across a year.
Talk it through with an engineer.
No call centre — you speak to Ted directly.