Glass door vs open display fridges: which is right for your shop?
Convenience stores, farm shops, delis and forecourts all rely on display refrigeration to sell chilled food and drinks. One of the biggest decisions when fitting out or replacing cabinets is whether to choose open-fronted multidecks or cabinets with glass doors.
Both work, and both are common. This guide compares them on the things that matter day to day: how customers shop them, how much energy they use, how steadily they hold temperature, the effect on the shop and what they need in maintenance.
Need this sorted?
Get a quote from TMS for display refrigeration cabinets.

How each type works
An open multideck has no doors. It keeps products cold with a curtain of cold air blown from the top of the cabinet down across the front to a return grille at the bottom. That air curtain separates the cold display from the warm shop.
A glass door cabinet uses doors with double or triple glazing to hold the cold in, with the refrigeration system cooling the enclosed space. Doors may be hinged or sliding, and some designs retrofit doors onto existing multidecks.
Customer access and sales
Open cabinets are quick to shop, with nothing between the customer and the product, which suits grab-and-go lunches and busy periods. Glass doors add a small step but still give full visibility, and modern doors are light and easy to open. Many shops find that clear signage and good lighting matter more than the doors themselves.
Energy use
The air curtain on an open cabinet is constantly mixing with warm shop air, so open cabinets generally use more energy to hold the same temperature than equivalent cabinets with doors. Draughts, air conditioning outlets and nearby doors disturb the curtain and make it worse.
Glass doors greatly reduce that exchange. For businesses looking to cut refrigeration energy use, doors are one of the most effective changes. Our guide to reducing commercial refrigeration energy costs covers other options.
Temperature stability
Open cabinets are sensitive to their surroundings. Overfilling past the load line, blocking the return grille or a nearby draught can break the air curtain and let products warm up. Glass door cabinets are more forgiving and tend to hold steadier product temperatures, especially in warm weather.
Shop comfort
Open multideck aisles spill cold air onto the floor, which many customers and staff notice as cold feet in winter. With integral cabinets, the heat rejected by the condensers also warms the shop in summer. Glass doors keep the aisle more comfortable, and remote systems move condenser heat outside.
Condensation and doors
Glass doors can mist up in humid conditions. Many cabinets use heated glass or frames to control this. If doors mist badly or seals wear, the cabinet works harder and products are harder to see, so door heaters and seals should be checked during servicing.
Maintenance differences
- Open cabinets: keep return grilles clear, respect load lines, check night blinds and air curtain fans
- Glass door cabinets: check door seals, hinges, closers and anti-mist heaters
- Both: condenser cleaning, defrost checks, controller and probe checks, lighting
Loading and merchandising
Open cabinets have a load line marked inside. Stock stacked above it sits outside the air curtain and warms up, and it also disrupts the curtain for everything else. Glass door cabinets are less sensitive, but overfilling still blocks airflow from the evaporator. In both types, rotating stock and keeping shelves tidy helps temperatures and sales.
Replacing or upgrading displays
When cabinets reach the end of their life, it is a good moment to rethink the layout, the mix of open and door cabinets, and whether integral or remote refrigeration suits the shop. Older displays may also use refrigerants affected by the F-Gas phase-down. A survey can look at all of these together rather than replacing like for like by default.
Lighting and visibility
Modern display cabinets typically use LED lighting, which gives good visibility and adds less heat than older lighting. Whatever the cabinet type, clean glass, working lights and tidy shelves make the biggest difference to how products look. If lights flicker or fail, or glass mists constantly, include them in your next service visit.
Which should you choose?
Siting matters as much as type. Keep any cabinet away from entrance doors, heaters and air conditioning outlets.
- Open cabinets suit fast grab-and-go sales and very high footfall
- Glass doors suit businesses focused on energy use, steadier temperatures and a comfortable shop
- Night blinds on open cabinets help cut energy use outside trading hours
- A mix is common: open for lunch items, doors for drinks and dairy
Want a professional to handle it?
Related services
- Display refrigeration cabinets
- Commercial refrigeration repairs
- Cold room installation and repair
- Ice machine installation, servicing and repair
Covering Hertfordshire, Buckinghamshire, Bedfordshire and London.
FAQs
Common questions
Do glass door fridges use less energy than open fridges?
Generally yes. Doors greatly reduce the mixing of warm shop air with the cold display, so the system works less.
Why is my open display fridge not keeping cold?
Overfilling past the load line, blocked return grilles, draughts or nearby air conditioning can break the air curtain. Faults also play a part.
Why do my fridge glass doors mist up?
High humidity or failed anti-mist heaters. Worn seals can also let moist air in.
Can doors be added to an open multideck?
Some cabinets can be retrofitted with doors. Whether it suits yours depends on the model and condition.
Which type is easier to maintain?
Both need condenser cleaning and defrost checks. Open cabinets need clear return grilles and night blinds; glass door cabinets need door seals and heaters checked.
Keep reading
More from our knowledge base
Cost & process guides
Where to put a commercial fridge or freezer for reliable cooling
The same fridge can run happily for years in one spot and break down repeatedly in another; where you put it matters.
Fault & symptom guides
Air Conditioning Blowing Warm Air
Warm air from a unit that should be cooling usually means either a settings mix-up or a refrigerant fault, and telling the two apart matters.
Fault & symptom guides
Noisy Outdoor Air Conditioning Unit
Not all outdoor unit noises mean the same thing, and the type of noise usually points straight to the cause before an engineer even arrives.