Air conditioning pipework explained: routes, lengths and trunking
When people picture air conditioning they think about the indoor unit and maybe the box outside. The pipework that joins them gets less attention, yet it decides how neat the finished job looks, how far apart the units can be and a good share of the installation work.
This guide explains what runs between the units, the rules that limit pipe routes, the options for hiding or covering the pipes, and what a careful installer does to protect them.
Planning a new system? See our air conditioning installation service.
Need this sorted?
Get a quote from TMS for air conditioning and refrigeration installations.

What actually runs between the units
Together these are often called the line set. The copper pipes are part of the sealed refrigerant circuit, so their joints must be made properly, pressure tested and the system evacuated before it is commissioned. That is regulated F-Gas work.
- Two copper refrigerant pipes, one larger and one smaller, each separately insulated
- A power and communication cable linking the indoor and outdoor units
- A condensate drain from the indoor unit, which may run with the pipes or separately
How long can the pipes be?
Every manufacturer sets a maximum pipe length and a maximum height difference between indoor and outdoor units for each model. Longer runs may need extra refrigerant added, and going beyond the limits reduces performance and can affect warranty terms.
Within those limits, shorter is generally better: fewer joints, less refrigerant, less cost and less to go wrong. A survey looks for the shortest sensible route that still puts each unit in the right place.
The neatest route: straight through the wall
Where the indoor unit sits on an external wall, the pipes can go straight out through a cored hole behind the unit and down the outside wall to the outdoor unit. Inside, almost nothing is visible. This is the simplest, neatest arrangement and the one we look for first.
When pipes have to travel
If the indoor unit needs to be on an internal wall, or the outdoor unit can only go on the other side of the building, the pipes have to travel. Options include running them through loft spaces, ceiling voids, floor voids or cupboards, or along walls in trunking.
Each extra metre adds materials and labour, and some routes need floorboards lifting or ceilings opening. That is why two quotes for the same unit in the same room can differ: one may assume a much longer or harder pipe route.
Trunking and covers
Where pipes run on the surface, plastic trunking gives a tidy, paintable finish indoors. Outside, pipe covers or trunking protect the insulation from sunlight and damage and look neater than bare lagging. Exposed insulation breaks down in UV light over time, which harms efficiency.
Condensate drains
The drain must fall continuously from the indoor unit to its outlet so water runs away by gravity. If that is impossible, for example where the unit sits below the drain point, a condensate pump is fitted. Poorly laid drains are one of the most common causes of water leaks indoors. Our condensate drainage guide explains the options.
Insulation and why it matters
Both refrigerant pipes are insulated. The insulation stops the cold suction pipe dripping condensation inside walls and ceilings, and reduces heat gain or loss along the run so the system works efficiently. Damaged, missing or poorly joined insulation shows up as damp patches, drips or ice on the pipes, and it is one of the things checked on a service visit.
Height differences and multi-storey routes
When the outdoor unit is much higher or lower than the indoor unit, for example on a flat roof above a ground-floor room, the manufacturer's height limits and oil return requirements come into play. A good installer checks these at survey stage, because breaking them can cause poor performance and compressor wear. Multi-split systems have their own limits for each branch.
Pipework on commercial jobs
In offices and shops, pipework often runs above suspended ceilings, along service routes or through risers, and may need fire stopping where it passes through compartment walls or floors. Longer runs and multiple indoor units are common, so planning routes with the building manager early saves rework. Neat, labelled, well-supported pipework also makes later servicing and fault finding much quicker.
Reusing existing pipework
When replacing an old system, people often ask whether the old pipes can be reused. Sometimes they can, after checking size, condition and cleanliness, but it depends on the new model's requirements and the old refrigerant. Often new pipework is the more reliable choice. An engineer can advise on site.
Want a professional to handle it?
Related services
- Air conditioning and refrigeration installations
- Home air conditioning
- Air conditioning maintenance contracts
- Cold room installation and repair
Covering Hertfordshire, Buckinghamshire, Bedfordshire and London.
FAQs
Common questions
How far can the outdoor unit be from the indoor unit?
It depends on the model. Each manufacturer sets maximum pipe lengths and height differences, and longer runs may need extra refrigerant.
Can air conditioning pipes be hidden?
Often, yes, through walls, lofts, ceiling voids, floors or cupboards. Where that is not possible, trunking gives a tidy finish.
Why do some installations have long white trunking?
Trunking covers pipes that cannot go straight through the wall, protecting them and giving a neater look than bare insulation.
Can I reuse my old air conditioning pipes?
Sometimes, if they are the right size and in good, clean condition. An engineer needs to check, and new pipework is often more reliable.
Keep reading
More from our knowledge base
System & comparison guides
Air conditioning and allergies: filters, cleaning and indoor air
A clean, well-maintained system filters dust and dries the air, but a neglected one can blow dust and mould spores straight back into the room.
Cost & process guides
F-Gas records for businesses: what to keep and why
If your business operates air conditioning or refrigeration above certain refrigerant thresholds, you are responsible for keeping records of leak checks, repairs and refrigerant handling.
Fault & symptom guides
Commercial fridge door seals: signs of failure and when to replace
A split or flattened door seal lets warm, moist air into a fridge or cold room every minute of the day, and it is one of the cheapest faults to fix.