Open-plan offices bring their own cooling problems: uneven glazing gains, clashing desk preferences, and complaints from whoever sits nearest the vent.

Open-plan layouts are popular because they're flexible and cheap to reconfigure, but they're genuinely harder to cool evenly than a building split into individual rooms. One large volume of air, mixed occupancy densities, and glazing that runs the length of one wall all combine to create hot spots and cold spots that a single thermostat can't fix.

We fit and service air conditioning in open-plan offices across Hertfordshire and the surrounding counties regularly, and the recurring theme is that the layout of the system matters as much as its total capacity. A correctly sized system poorly zoned still leaves half the floor unhappy.

Air conditioning for open-plan offices

Why open-plan offices are harder to cool than cellular ones

In a cellular office, each room has its own load and its own unit, so problems stay contained. In open-plan space, heat from solar gain on one side of the floor, from a bank of printers or a server cupboard, and from simple occupancy density near meeting pods all mix together in one shared volume of air. A single point of measurement, like a thermostat by the door, rarely reflects what's happening at the far end of the floor.

Desk layout changes also outlive the original air conditioning design. An office fitted out for 40 desks that later squeezes in 55 through hot-desking will find the original cooling capacity was never designed for that occupancy, even if nothing else about the space changed.

Zoning: the single biggest factor in open-plan comfort

Splitting an open floor into two or three independently controlled zones, each with its own indoor units, allows the glazed south side to run harder than the shaded north side without either area being sacrificed to a compromise setting. Zoning is usually achieved with multiple cassette units or a multi-split arrangement, each set responding to its own local conditions rather than one thermostat trying to represent the whole floor.

Zoning also solves the recurring workplace argument over who controls the thermostat. Give each zone its own control, ideally somewhere central and out of reach of the person who sits directly under the nearest vent, and most day-to-day complaints disappear on their own.

Dealing with glazing gains

Large glazed frontages, common in modern office buildings and business parks, can add a substantial cooling load on sunny afternoons that has nothing to do with occupancy. Solar film, internal blinds or external shading all reduce the load reaching the room before it becomes something the air conditioning has to work against.

Where glazing can't be treated, for example in listed or leased buildings with restrictions on external changes, the cooling design needs to account for that load directly rather than assume a standard office heat gain figure. This is exactly the kind of detail a proper site survey picks up that a rough online cost estimate never will.

Cassette layout for even coverage

  • Ceiling cassettes throwing air in four directions generally give more even coverage across open floor plates than a row of wall units all facing one way.
  • Space cassettes to avoid overlapping cold zones near desks directly beneath them and dead zones between units.
  • Keep return air paths clear of partitions, storage and printer stations that can starve a cassette of the air it needs to recirculate properly.
  • Position controllers away from direct airflow paths so temperature readings aren't skewed by a nearby vent.

Managing complaints once the system is in

Even a well-designed system generates the odd complaint, usually from people directly under a vent or furthest from one. Having a facilities contact who can adjust louvre direction, fan speed or zone setpoints without calling an engineer for every tweak resolves most of these quickly. Where complaints persist despite reasonable adjustment, it's often a sign the original zoning needs revisiting rather than something wrong with individual desks.

If your open-plan office is stuck with hot desks by the window and a queue of complaints every summer, it's worth having someone look at the zoning rather than just adding another portable unit. Get in touch for a free quote and site survey, and we'll assess how the space is actually being used before recommending a layout.

FAQs

Common questions

How many zones does a typical open-plan office need?

It depends on floor size and glazing, but most medium open-plan floors benefit from at least two or three independently controlled zones rather than one system covering everything.

Is ceiling cassette always better than wall-mounted for open-plan space?

Generally yes for coverage evenness, because cassettes throw air in multiple directions, though wall units can still work well in smaller or narrower open areas.

Can existing air conditioning be re-zoned without a full replacement?

Sometimes, if the outdoor unit has spare capacity and the indoor units support independent control, but a survey is needed to confirm this rather than assuming it's possible.

Does hot-desking affect air conditioning sizing?

Yes, higher occupancy density than the original design assumed can outstrip cooling capacity, particularly on hot days, even if the floor area hasn't changed.

What's the quickest fix for a persistently hot corner of an open-plan office?

Check glazing shading first, since it's often the cheapest fix, before assuming more cooling capacity is needed.