Variable refrigerant flow systems

VRF air conditioning for larger offices and commercial buildings.

VRF and VRV system design, installation and maintenance for multi-room commercial buildings across Hertfordshire, Buckinghamshire, Bedfordshire and London.

Planning cooling for a larger building? Call Ted for a free survey and honest advice on whether VRF is right for it.

Call 07940 953486 now

VRF air conditioning is the standard answer for larger commercial buildings: one outdoor installation feeding a network of indoor units, each controlling its own room. Because the system modulates the refrigerant flowing to each unit, it runs efficiently at part load, which is how big buildings actually operate most of the time.

VRF is a bigger commitment than split systems and it is not right for every building. Our VRF vs split systems guide sets out the trade-offs honestly, and for smaller premises multi-split air conditioning is often the more sensible spend.

  • One outdoor unit serving many indoor units
  • Individual temperature control room by room
  • Heat recovery options for mixed-use buildings
  • Wall, cassette and ducted indoor units mixed on one system
  • Phased installation to keep you trading
  • Central controllers and zone scheduling
  • Daikin, Mitsubishi Electric and other makes
  • Refcom F-Gas certified engineers
VRF air conditioning for larger offices and commercial buildings.

Where VRF earns its keep

Multi-floor offices, hotels, schools, clinics and larger retail or leisure buildings are the classic VRF candidates: anywhere with many rooms, varied occupancy and a limit on how many outdoor units the building can take. Heat recovery models suit buildings where one side overheats while the other still needs warmth, moving heat between the two instead of throwing it away.

Design and installation

A VRF project starts with a proper design: room-by-room heat loads, a pipework schematic, outdoor unit siting and a controls plan. Indoor units can be mixed on the same system, so open-plan areas can have ceiling cassettes, offices ducted units and smaller rooms wall units. Installation is normally phased so occupied areas stay usable, and every pipe joint is pressure tested before the system is charged.

Controls and running costs

Central controllers let facilities staff set schedules, lock temperatures and see faults across the whole system from one screen. Zone control matters more than most people expect: an empty meeting room holding 21 degrees all weekend is pure waste, and scheduling alone often makes a noticeable dent in running costs.

Maintenance

A VRF system is a single point of failure for a whole building, so planned maintenance is not optional in any real sense. Our air conditioning maintenance contracts cover VRF systems with scheduled visits, F-Gas leak checks where the charge requires them, and a written record per visit. See also commercial air conditioning and our guide to commercial systems.

Why choose us

A specialist you can trust on site.

Designed room by room, not by rule of thumb

Refcom F-Gas certified and insured

30+ years on the tools

Based in Hemel Hempstead

Recent work

Examples of variable refrigerant flow systems projects.

Variable refrigerant flow systems project 1
Variable refrigerant flow systems project 2
Variable refrigerant flow systems project 3

How it works

A simple, transparent process.

  1. 01

    Survey

    Building walked, loads and layout assessed.

  2. 02

    Design

    Pipe schematic, unit selection and controls plan.

  3. 03

    Quote

    Written proposal with a phased programme.

  4. 04

    Install

    Pipework, indoor units and outdoor plant fitted.

  5. 05

    Commission

    Pressure tested, charged and handed over.

Get a quote

Tell us what you need.

Send your details and a short description, or call 07940 953486. Standard hours are Monday to Friday, 08:00 to 17:00.

Send us a message

Free, no-obligation · Friendly local team · 24h response

FAQs

Frequently asked questions

What does VRF mean?

Variable Refrigerant Flow. One outdoor unit (or a bank of them) serves many indoor units, and the system varies the amount of refrigerant sent to each one so every room gets the cooling or heating it actually needs.

What is the difference between VRF and VRV?

They are the same type of system. VRV is Daikin's trademarked name for its variable refrigerant volume range; VRF is the generic term every other manufacturer uses.

Can a VRF system heat and cool at the same time?

Heat recovery VRF systems can: heat taken from rooms being cooled is moved to rooms that need warming. Heat pump VRF systems run the whole building in either cooling or heating at one time. We fit air-to-air systems only.

Is VRF right for a small office?

Usually not. VRF earns its keep from around eight to ten indoor units upwards. Smaller buildings are often better served by multi-split systems, which are simpler and cheaper to install.

How long does a VRF installation take?

Longer than a split system, because of the pipe network and the number of indoor units. Work is usually phased area by area so the building stays usable, and we agree the programme with you before starting.

Service areas

VRF air conditioning across Hertfordshire & the South East

Local vrf air conditioning engineers covering Hertfordshire, Buckinghamshire, Bedfordshire and the edges of London. Pick your town for area-specific information.

Ready to get started?

Speak directly to Ted for professional advice and a free quotation.

Call WhatsApp Get a quote